12345678910111213141516171819A0.00COVERARCHITECTJEFF SPIKES1301069572318-828-1637NAME:LICENSE NO.:PHONE NO.:LOCATED AT:45001 SCHOENHERR RDUTICA, MI 48315SMOKEY BONESPROFESSIONAL OFRECORD:ALL CONSTRUCTION TO COMPLY WITH LOCAL AND STATE CODES AND STANDARDSCORRECTING SUCH VIOLATIONS.BEEN MADE, WILL NOT BE ALLOWED.CONTRACTOR NOTESSUBMITTING A BID. REPORT ANY DISCREPANCIES TO ARCHITECT OREXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE ANDSCOPE OF THE WORK. THE SUBMISSION OF A BID WILL BE EVIDENCETHAT SUCH AN EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR LABOR,EQUIPMENT, OR MATERIALS REQUIRED, OR FOR ANY DIFFICULTIESIT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ARCHITECT,AND OWNER OF ANY DISCREPANCIES ENCOUNTERED ON THE PLANS OR IN CONTRACTORS ARE CAUTIONED TO COORDINATE ITEMS IN THEIR SCOPE OFWORK WITH OTHER TRADES.EXISTING SITE CONDITIONS PRIOR TO SUBMISSION OF BID.ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HAD AN EXAMINATIONVISUALLY APPARENT CODE VIOLATIONS AND ALLOW IN HIS/HER BID FORCONTRACTOR, DURING PRE-BID SITE VISIT, SHALL TAKE NOTICE OF ANYSPECIFICATIONS , INCLUDING BUT NOT LIMITED TO ARCHITECTURAL, CIVIL, STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL PRIOR TOIT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW ALL DRAWINGS ANDBIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITHE.F.D.C.B.ENGINEER PRIOR TO BID.A.I.THESE NOTES APPLY TO ALL SHEETS.G.CONTRACTOR TO PROVIDE LOW LEVEL EXIT SIGNAGE WITH BRAILLE AT ALLREQUIRED EXITS.H.CONTRACTOR IS VERIFY EXISTING BACKFLOW PREVENTER IS PRESENT AND WORKINGPROVIDE NEW OR REPAIR AS NEEDEDSHEET INDEXA0.00COVERA0.01LIFE SAFETYA1.01ARCHITECTURAL SITE PLANA2.00DEMO FLOOR PLANA2.01FLOOR PLANA2.02FURNITURE PLAN LAYOUTA2.03EXISTING ROOF PLANA2.04ROOF PLANA2.05KITCHEN EQUIPMENT PLANA2.06BAR ROUGH-IN PLANA2.07KITCHEN ROUGH-IN PLANA3.01DOOR AND WINDOW AND DETAILSA4.00EXISTING EXTERIOR ELEVATIONSA4.01EXISTING EXTERIOR ELEVATIONSA4.02EXTERIOR ELEVATIONSA4.03EXTERIOR ELEVATIONSA5.01RESPONSIBILITY MATRIXA6.01RESTROOM PLAN & DETAILSA6.02INTERIOR ELEVATIONSA6.03INTERIOR ELEVATIONSA7.01REFLECTED CEILING PLANA8.01STANDARD MOUNTING HTS AND MISC DETAILSA9.01BAR SECTIONS & DETAILSA9.02BAR SECTIONS & DETAILSA9.03BAR TRELLIS PLANA9.04BAR TRELLIS DETAILSSTRUCTURALSG-01GENERAL NOTESSG-02SPECIAL INSPECTIONS & TESTINGSG-03SPECIFICATIONSSP-01FOUNDATION PLANSP-02ROOF FRAMING PLANS5-01SECTIONSELECTRICALE1.0FLOOR PLAN - LIGHTINGE2.0FLOOR PLAN - POWERE2.1ROOF PLAN - ELECTRICALE3.0ELECTRICAL SCHEDULES AND DETAILSE3.1ELECTRICAL SCHEDULES AND DETAILSE3.2ELECTRICAL SCHEDULES AND DETAILSFIRE PROTECTIONFP1.0FLOOR PLAN - FIRE PROTECTIONMECHANICALM1.0FLOOR PLAN - HVACM2.0ROOF PLAN - MECHANICALM3.0MECHANICAL SCHEDULES AND DETAILSM3.1MECHANICAL SCHEDULES AND DETAILSM4.0CAPTIVEAIRE SCHEDULES AND DETAILSM4.1CAPTIVEAIRE SCHEDULES AND DETAILSM4.2CAPTIVEAIRE SCHEDULES AND DETAILSM4.3CAPTIVEAIRE SCHEDULES AND DETAILSM4.4CAPTIVEAIRE SCHEDULES AND DETAILSM4.5CAPTIVEAIRE SCHEDULES AND DETAILSDEMOLITIONMEP1.0FLOOR PLAN - DEMOLITIONMEP1.1ROOF PLAN - DEMOLITIONPLUMBINGP1.0PLUMBING SANITARY PLANP1.1PLUMBING WATER & GAS PLANP2.0ENLARGED PLAN - SANITARY PLANP2.1ENLARGED PLAN - WATER AND GAS PLANP3.0PLUMBING SCHEDULES AND DETAILSP3.1PLUMBING SCHEDULES AND DETAILSP3.2PLUMBING SCHEDULES AND DETAILSSYMBOL LEGENDLOCATOR MAPSEE DOOR SCHEDULENEW DOORAWALL SECTION MARKERDOOR NUMBER, SEE SCHEDULEFINISH ELEVATIONINTERIOR ELEVATION/ LOCATIONROOM NAME/ ROOM NUMBERWINDOW NUMBER, SEE SCHEDULESECTION DETAIL/ SHEETBUILDING SECTION MARKER100ROOM NAME0.0A0.0SECTION DETAIL MARK0.0A0.0ENLARGED REFERENCE0.000.0A0.0EL.000.0'A.F.F.101000.0A0.0JEFF SPIKES ARCHITECT417 LAKE STREETSHREVEPORT, LOUISIANA 71101SITECODE INFORMATION:1AB23CD456ABCD123456DATE 11/12/21REVISIONSNO.DATEPROJECT NO:IA 2119SHEETSMOKEY BONESUTICA, MICOPYRIGHTTHESE DOCUMENTS ARE PROTECTED BY UNITED STATESCOPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLYFOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FORUSE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATIONWITHOUT THE EXPRESS WRITTEN APPROVAL ANDPARTICIPATION OF iARCHITECTURE. REPRODUCTION OFTHESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.ALL RIGHTS ARE RESERVED TO iARCHITECTURE.STATEOFMICHIGANARCHITECTJEFFSPIKESNUMBER1301069572JEFF SPIKES, ARCHITECTLICENSE NO. 1301069572CODES UTILIZEDFIRE/ LIFE SAFETY CODE:INTERNATIONAL FIRE CODE, 2015 EDACCESSIBILITY CODE:2009 ANSI A117.1BUILDING CODE:MI BUILDING CODE, 2015 EDPLUMBING CODE:MI PLUMBING CODE, 2015 EDFUEL GAS CODE:INTERNATIONAL FUEL GAS CODE, 2015 EDMECHANICAL CODE:MI MECHANICAL CODE, 2015 EDELECTRICAL CODE:NEC ELECTRICAL CODE, 2014 EDSMOKER03.0SMOKER03.0HHHHHHHHHHHHHHHHHHHHPOSPOSPOSCOOLERDRY STORAGEEXISTINGMECH/ELECPOSCOOLERFREEZERPOSHALF WALLOFFICE24" x 54"24" x 54"24" x 54"21" x 60"A0.01LIFE SAFETYPLAN1AB23CD456ABCD123456DATE 11/12/21REVISIONSNO.DATEPROJECT NO:IA 2119SHEETSMOKEY BONESUTICA, MICOPYRIGHTTHESE DOCUMENTS ARE PROTECTED BY UNITED STATESCOPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLYFOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FORUSE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATIONWITHOUT THE EXPRESS WRITTEN APPROVAL ANDPARTICIPATION OF iARCHITECTURE. REPRODUCTION OFTHESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.ALL RIGHTS ARE RESERVED TO iARCHITECTURE.STATEOFMICHIGANARCHITECTJEFFSPIKESNUMBER1301069572JEFF SPIKES, ARCHITECTLICENSE NO. 1301069572A1LIFE SAFETY PLAN3/16" = 1'-0"LEGENDOCCUPANCY TYPE: SMOKEY BONES BBQ RESTAURANTBUILDING CONSTRUCTION TYPE:BUILDING USE:CODE INFORMATION:TRAVEL DISTANCE REQUIRED:250' MAX. COMMON PATH REQUIRED:20' (50 OR MORE OCCUPANTS) / 75' (LESS THAN 50 OCCUPANTS) MAX CODES ENFORCED:DEAD END CORRIDOR:20' MAXRESTAURANTTOTAL OCCUPANT LOAD:FIRE ALARMFIRE ALARM PROVIDED PER THE 2014 INDIANA FIRE PREVENTION CODESCOPE OF WORK:RESTAURANT CONVERSION (EXISTING TGI FRIDAY'S TO SMOKEY BONES)DINING ROOMA-2OCCUPANCY OCCUPANCY CLASSIFICATION (304)GROUP A - 2 ASSEMBLY (RESTAURANT)TYPE VI - UNPROTECTED, SPRINKLERED (EXISTING)CONSTRUCTION TYPE (608)3.AREA ALLOWANCES (TABLE 500)2.1.MAX. HEIGHT40'-0" (PER CODE)1MAX. STORIESALLOW. AREA15,000 SF 6,866 SFACTUAL AREA25'-0" (PER DEVELOPER)FLOOR11OCCUPANTS3,185 NET SFOCCUPANCYAREA1,938 SFTOTAL SEATSMIN. OCC. LOAD100/PERSON20262--WAITING11155 SF31WAITING (BAR)93 SF19BUSINESS5/PERSON5/PERSONCODES UTILIZEDFIRE/ LIFE SAFETY CODE:INTERNATIONAL FIRE CODE, 2015 EDACCESSIBILITY CODE:2009 ANSI A117.1BUILDING CODE:MI BUILDING CODE, 2015 EDPLUMBING CODE:MI PLUMBING CODE, 2015 EDFUEL GAS CODE:INTERNATIONAL FUEL GAS CODE, 2015 EDMECHANICAL CODE:MI MECHANICAL CODE, 2015 EDELECTRICAL CODE:NEC ELECTRICAL CODE, 2014 ED9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"19'-1"A1.01SITE PLANA1SITE PLAN1/16" = 1'-0"1AB23CD456ABCD123456DATE 11/12/21REVISIONSNO.DATEPROJECT NO:IA 2119SHEETSMOKEY BONESUTICA, MICOPYRIGHTTHESE DOCUMENTS ARE PROTECTED BY UNITED STATESCOPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLYFOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FORUSE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATIONWITHOUT THE EXPRESS WRITTEN APPROVAL ANDPARTICIPATION OF iARCHITECTURE. REPRODUCTION OFTHESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.ALL RIGHTS ARE RESERVED TO iARCHITECTURE.STATEOFMICHIGANARCHITECTJEFFSPIKESNUMBER1301069572JEFF SPIKES, ARCHITECTLICENSE NO. 1301069572CHCHHC1'-4"13'-8"3'-4"2'-0 1/2"4'-10 1/2"4'-11 1/2"4'-10 1/2"A2.00DEMOFLOORPLAN1AB23CD456ABCD123456DATE 11/12/21REVISIONSNO.DATEPROJECT NO:IA 2119SHEETSMOKEY BONESUTICA, MICOPYRIGHTTHESE DOCUMENTS ARE PROTECTED BY UNITED STATESCOPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLYFOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FORUSE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATIONWITHOUT THE EXPRESS WRITTEN APPROVAL ANDPARTICIPATION OF iARCHITECTURE. REPRODUCTION OFTHESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.ALL RIGHTS ARE RESERVED TO iARCHITECTURE.STATEOFMICHIGANARCHITECTJEFFSPIKESNUMBER1301069572JEFF SPIKES, ARCHITECTLICENSE NO. 1301069572A1FLOOR PLAN3/16" = 1'-0"NOTES:·REMOVE ALL INTERIOR FINISHES IN FOH (FRONT OF HOUSE) AREAS AS REQUIRED BY EXTENT OF NEWWORK. THIS INCLUDES DINING ROOM, FRONT OF OFFICE, AND RESTROOMS.·ANY EXISTING WALLS OR SECTIONS OF WALLS MARKED WITH HATCH ARE TO BE DEMOLISHEDAS REQUIRED BY EXTENT OF NEW WORK.·ANY EXISTING ITEMS WHICH ARE TO REMAIN ARE TO BE PRESERVED AND PROTECTED FOR REUSE BY G.C.·ALL EXTERIOR FINISHES TO BE REMOVED AS NECESSARY FOR INSTALLATION OF NEW FINISHES.DEMOLITION PLAN KEYNOTES1.EXISTING RESTROOMS TO BE DEMOLISHED. THIS INCLUDES, BUT IS NOTLIMITED TO, REMOVAL OF ALL EXISTING PLUMBING FIXTURES AND CAPPINGOF EXISTING DRAIN LINES (SEE PLUMBING DRAWINGS), ALL EXISTINGFLOOR AND WALL FINISHES, EXISTING CEILINGS AND CEILING FIXTURES,EXISTING WALL PARTITIONS, EXISTING MILLWORK, EXISTING DUCTWORKAND MECHANICAL FIXTURES (SEE MECHANICAL DRAWINGS), EXISTINGDOORS, AND EXISTING WALLS AS NOTED.2.ALL EXISTING KITCHEN EQUIPMENT TO BE REMOVED. THIS INCLUDESFREESTANDING EQUIPMENT, HOODS (SEE MECHANICAL DRAWINGS), ANDFLOOR OR WALL MOUNTED EQUIPMENT. THIS DOES NOT INCLUDE WALK-INFREEZERS/COOLERS UNLESS OTHERWISE NOTED.3.REMOVE EXISTING ROOF LADDER. EXISTING HATCH DOOR TO REMAIN ANDBE LOCKED PRIOR TO BEING COVERED BY NEW CEILING GRID.4.EXISTING WALL FINISHES TO BE REMOVED AND WALLS TO BE PREPPED FORINSTALLATION OF NEW WALL FINISHES.5.EXISTING STRUCTURAL COLUMNS TO REMAIN, EXCEPT AS NOTED ON DEMOFLOOR PLAN AND STRUCTURAL DRAWINGS, TYPICAL.6.REMOVE EXISTING ELEVATOR AND ALL RELATED ELECTRICAL, MECHANICAL,AND HYDRAULIC EQUIPMENT.7.DEMOLISH EXISTING CONCRETE PLATFORMS/STEM WALLS AS NECESSARYTO BRING FLOOR TO BE FLUSH WITH LOWER LEVEL FLOOR ELEVATIONS.8.DEMOLISH EXISTING UPPER FLOOR AREA AND CRAWLSPACE ASNECESSARY TO BRING FLOOR TO BE FLUSH WITH LOWER LEVEL FLOORELEVATIONS. THIS INCLUDES EXISTING WOOD AND CONCRETESTRUCTURES, STAIRS, PLATFORMS, ELECTRICAL, MECHANICAL, PLUMBING,AND SPRINKLERS.9.REMOVE EXISTING EXTERIOR WALK-IN COOLER, INCLUDING ALLMECHANICAL EQUIPMENT, FENCING, AND SLAB. PREPARE AREA FORINSTALLATION OF NEW WALK-IN COOLER. PRESERVE EXISTING OPENING INEXTERIOR WALL TO BE REUSED WITH NEW WALK-IN COOLER.10.EXISTING WINDOWS TO BE REMOVED OR BLACKED OUT AND COVEREDWITH NEW WALL CONSTRUCTION.11.REMOVE EXISTING WINDOWS AND A PORTION OF EXISTING WALLS ASREQUIRED TO INSTALL NEW WINDOWS FLUSH WITH FINISH FLOOR.12.REMOVE EXISTING STOREFRONT AND DOOR. PREPARE AREA FOR NEWSTOREFRONT INSTALLATION (SEE DOOR/WINDOW SCHEDULES.)13.REMOVE ALL INTERIOR FINISHES FROM DINING AREAS, INCLUDING (BUTNOT LIMITED TO) FLOORING, WALL FINISHES, CEILING GRID, LIGHTFIXTURES, CEILING ELEMENTS, ETC.14.REMOVE EXISTING EXTERIOR FINISH BUMPOUTS AS REQUIRED BY EXTENTOF NEW WORK.15.REMOVE ALL INTERIOR FINISHES AND REPLACE WITH NEW. EXISTINGMECHANICAL/ELECTRICAL EQUIPMENT TO BE REMOVED PER MEP DEMOPLAN. SEE MECHANICAL/ELECTRICAL DRAWINGS.16.REMOVE EXISTING DOOR(S).COOLERDRY STORAGEEXISTINGMECH/ELECCOOLERFREEZERHALF WALLOFFICE21" x 60"1'-9"2'-0"5'-7 3/8"2'-0"3'-3"3'-3"37'-9 1/4"15'-6 1/4"5'-10 3/4"6'-6 1/4"5'-1"5'-7"3'-4 1/4"3'-4 1/4"4'-11 1/4"11'-3 3/4"4'-8"6'-3 1/2"5'-5 3/4"1'-6 1/4"5'-0 1/4"1'-5 1/4"2'-11 1/2"12'-10"8'-8 1/2"16'-8"12'-7"6'-2"5"2'-11 3/4"7'-8 3/4"3'-3 1/2"3'-10"3'-7 1/2"19'-11 1/2"6'-0"8'-1 1/2"6'-10 1/2"3'-0"3'-4"3'-10 1/2"16'-3 1/2"2'-8 3/4"7'-7"2'-10"7'-8 1/4"9'-10"16'-5 1/2"4'-0"8'-9 1/4"7'-8 3/4"6'-11 1/4"1'-4 1/4"17'-10 1/4"8'-0 3/4"10'-1 1/2"2'-6"8'-9 1/2"17'-5 3/4"5'-8 3/4"12'-10 1/4"NEW/RELOCATED STRUCTURALCOLUMN/FOOTING. SEE STRUCTURALDWGS FOR SIZING AND LOCATIONS.NEW/RELOCATED STRUCTURALCOLUMN/FOOTING. SEE STRUCTURALDWGS FOR SIZING AND LOCATIONS.NEW/RELOCATED STRUCTURALCOLUMN/FOOTING. SEE STRUCTURALDWGS FOR SIZING AND LOCATIONS.NEW/RELOCATED STRUCTURALCOLUMN/FOOTING. SEE STRUCTURALDWGS FOR SIZING AND LOCATIONS.FILL IN EXISTINGOPENINGSFILL IN EXISTINGOPENINGSHALF WALLHALF WALLHALF WALL6" UNDER SLAB CONDUITFOR SODA LINES. SEE D4THIS SHEET. 6" UNDER SLAB CONDUITFOR BEER LINES. SEE D4 THIS SHEET.NEW EXTERIOR FLOOR SINK4 7/8"3 5/8"5/8"5/8"5/8" TYPE 'X'GYP. BD.5/8" TYPE 'X'GYP. BD.2X4 WOODSTUDS @16" O.C.INTERIORWALL FINISHAS SCHEDULEDINTERIORWALL FINISHAS SCHEDULED6 3/4"5 1/2"5/8"5/8"5/8" TYPE 'X'GYP. BD.5/8" TYPE 'X'GYP. BD.2X6 WOODSTUDS @16" O.C.INTERIORWALL FINISHAS SCHEDULEDINTERIORWALL FINISHAS SCHEDULED7 1/4"6"5/8"5/8"5/8" TYPE 'X'GYP. BD.5/8" TYPE 'X'GYP. BD.6" METALSTUDS @16" O.C.INTERIORWALL FINISHAS SCHEDULEDINTERIORWALL FINISHAS SCHEDULED3/4" PLYWOOD2X4 WOODSTUDS @16" O.C.3/4" CORRUGATEDMETAL PANELS5"3 5/8"5/8"3/4"5/8" TYPE 'X'GYP. BD.INTERIORWALL FINISHAS SCHEDULEDA2.01FLOORPLAN1AB23CD456ABCD123456DATE 11/12/21REVISIONSNO.DATEPROJECT NO:IA 2119SHEETSMOKEY BONESUTICA, MICOPYRIGHTTHESE DOCUMENTS ARE PROTECTED BY UNITED STATESCOPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLYFOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FORUSE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATIONWITHOUT THE EXPRESS WRITTEN APPROVAL ANDPARTICIPATION OF iARCHITECTURE. REPRODUCTION OFTHESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.ALL RIGHTS ARE RESERVED TO iARCHITECTURE.STATEOFMICHIGANARCHITECTJEFFSPIKESNUMBER1301069572JEFF SPIKES, ARCHITECTLICENSE NO. 1301069572A1FLOOR PLAN3/16" = 1'-0"D5INTERIOR WALL TYPE A1-1/2" = 1'-0"TYPICAL UNLESS OTHERWISE NOTEDC5INTERIOR WALL TYPE B1-1/2" = 1'-0"B5INTERIOR WALL TYPE C1-1/2" = 1'-0"A5INTERIOR WALL TYPE D1-1/2" = 1'-0"D4UNDERGROUND BEER/SODA CONDUIT DETAILN.T.S.UNDERGROUND BEER/SODA CONDUIT NOTES·G.C. IS RESPONSIBLE TO COORDINATE INFORMATION WITH PLUMBERS ANDFOUNDATION CONTRACTORS FOR INSTALLATION.·PLUMBERS MUST USE 6" ELECTRICAL PVC PIPE THAT IS SEAMLESS ON INSIDE OFTHE PIPE JOINTS.·ALL JOINTS MUST BE SOLVENT CEMENTED IN ACCORDANCE WITH PVCMANUFACTURER'S RECOMMENDATIONS TO GUARANTEE A WATERTIGHT CHASE.·ONLY ONE 90° ELECTRICAL SWEEP MAY BE USED AT EACH END OF THE CHASE.·BACK TO BACK SWEEPS SWITCHING DIRCTIONS CANNOT BE USED.·CONDUIT MUST BE CAPPED AND SEALED AT BOTH ENDS DURINGCONSTRUCTION.·INSTALLER MUST TRIM EXPOSED ENDS TO FOUR INCHES ABOVE FINISHEDFLOOR DURING PRODUCT LINE INSTALLATION.·THE SWEEPS MUST BE 90° ELECTRICAL SWEEPS AS SHOW IN ILLUSTRATION.·AT NO TIME CAN YOU USE ANY STRAIGHT 90 DEGREE BENDS - THEY MUST BESWEEPING.·COORDINATE EXACT LOCATIONS WITH OWNER AND/OR EQUIPMENT PROVIDERPRIOR TO CONDUIT CHASE INSTALLATION.NOTES:·HATCHED WALLS DENOTE NEW WALL CONSTRUCTION·KITCHEN TO HAVE ALL NEW WHITE FRP INSTALLED THROUGHOUT·SMOKER ROOM TO HAVE STAINLESS STEEL WALL PANELS INSTALLED INSTEADOF FRP.·MECHANICAL/SPRINKLER ROOM TO HAVE NEW FRP OR APPROVED EQUALINSTALLEDHHHHHHHHHHHHHHHHHHHHPOSPOSPOSPOSPOSHALF WALL24" x 54"24" x 54"24" x 54"21" x 60"A2.02FURNITUREPLAN LAYOUTA1FURNITURE PLAN LAYOUT3/16" = 1'-0"1AB23CD456ABCD123456DATE 11/12/21REVISIONSNO.DATEPROJECT NO:IA 2119SHEETSMOKEY BONESUTICA, MICOPYRIGHTTHESE DOCUMENTS ARE PROTECTED BY UNITED STATESCOPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLYFOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FORUSE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATIONWITHOUT THE EXPRESS WRITTEN APPROVAL ANDPARTICIPATION OF iARCHITECTURE. REPRODUCTION OFTHESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.ALL RIGHTS ARE RESERVED TO iARCHITECTURE.STATEOFMICHIGANARCHITECTJEFFSPIKESNUMBER1301069572JEFF SPIKES, ARCHITECTLICENSE NO. 1301069572D1TYP. MENU HOLDER3" = 1'-0"D2TYP. MENU HOLDER3" = 1'-0"A2.03EXISTINGROOF PLANA1EXISTING ROOF PLAN3/16" = 1'-0"1AB23CD456ABCD123456DATE 11/12/21REVISIONSNO.DATEPROJECT NO:IA 2119SHEETSMOKEY BONESUTICA, MICOPYRIGHTTHESE DOCUMENTS ARE PROTECTED BY UNITED STATESCOPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLYFOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FORUSE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATIONWITHOUT THE EXPRESS WRITTEN APPROVAL ANDPARTICIPATION OF iARCHITECTURE. REPRODUCTION OFTHESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.ALL RIGHTS ARE RESERVED TO iARCHITECTURE.STATEOFMICHIGANARCHITECTJEFFSPIKESNUMBER1301069572JEFF SPIKES, ARCHITECTLICENSE NO. 1301069572±23'-1 3/4"FIELD VERIFY±19'-1 1/2"FIELD VERIFY10'-9 1/2"7'-9"17'-8 1/2"5'-0"2'-10"2'-10"1212131313129109109107344211KEF-1KEF-2KEF-3KEF-4EF-6EF-7RTU-1RTU-2KITCHENDOASEF-5666666888611212127'-7"14'-7"14'-6 1/2"6'-0"3'-0"6"7"MIN.7"MIN.ROOF LADDER DETAILA2.04ROOF PLANA1ROOF PLAN3/16" = 1'-0"1AB23CD456ABCD123456DATE 11/12/21REVISIONSNO.DATEPROJECT NO:IA 2119SHEETSMOKEY BONESUTICA, MICOPYRIGHTTHESE DOCUMENTS ARE PROTECTED BY UNITED STATESCOPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLYFOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FORUSE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATIONWITHOUT THE EXPRESS WRITTEN APPROVAL ANDPARTICIPATION OF iARCHITECTURE. REPRODUCTION OFTHESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.ALL RIGHTS ARE RESERVED TO iARCHITECTURE.STATEOFMICHIGANARCHITECTJEFFSPIKESNUMBER1301069572JEFF SPIKES, ARCHITECTLICENSE NO. 1301069572KEY NOTESREVKEYSPEC.DESCRIPTION1SINGLE PLY ROOFING MEMBRANE (DUROLAST OR APPROVED EQUIVALENT) OVER 4" RIGIDINSULATION2NEW STANDING SEAM METAL ROOF36" PREFINISHED ALUMINUM GUTTER46" PREFINISHED ALUMINUM DOWNSPOUT5EXISTING ROOF ACCESS HATCH TO BE LATCHED AND SEALED6NEW EXHAUST FANS7NEW EXTERIOR ROOF ACCESS LADDER8NEW ROOF TOP UNIT (RTU)9CONT. WALL SCREEN FRAME ANCHORED TO PARAPET WALL10CONT. BREAK METAL PARAPET COPING (COLOR: DARK BRONZE TYP.)11STEEL TRELLIS (REFER TO SECTIONS)12CANVAS AWNING. G.C. TO FIELD VERIFY DIMENSIONS PRIOR TO ORDERING/PRODUCTION.13NEW METAL AWNINGS. G.C. TO FIELD VERIFY DIMENSIONS PRIOR TO ORDERING/PRODUCTION.A5ROOF LADDER DETAIL3/4" = 1'-0"SMOKERSMOKERHHHHHHHHHHHHHHHHHHHHPOSPOSPOSHALF WALL24" x 54"24" x 54"24" x 54"21" x 60"A2.05KITCHENEQUIPMENTPLANA1KITCHEN EQUIPMENT PLAN3/16" = 1'-0"1AB23CD456ABCD123456DATE 11/12/21REVISIONSNO.DATEPROJECT NO:IA 2119SHEETSMOKEY BONESUTICA, MICOPYRIGHTTHESE DOCUMENTS ARE PROTECTED BY UNITED STATESCOPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLYFOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FORUSE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATIONWITHOUT THE EXPRESS WRITTEN APPROVAL ANDPARTICIPATION OF iARCHITECTURE. REPRODUCTION OFTHESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.ALL RIGHTS ARE RESERVED TO iARCHITECTURE.STATEOFMICHIGANARCHITECTJEFFSPIKESNUMBER1301069572JEFF SPIKES, ARCHITECTLICENSE NO. 1301069572A2.06BARROUGH-INPLAN1AB23CD456ABCD123456DATE 11/12/21REVISIONSNO.DATEPROJECT NO:IA 2119SHEETSMOKEY BONESUTICA, MICOPYRIGHTTHESE DOCUMENTS ARE PROTECTED BY UNITED STATESCOPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLYFOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FORUSE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATIONWITHOUT THE EXPRESS WRITTEN APPROVAL ANDPARTICIPATION OF iARCHITECTURE. REPRODUCTION OFTHESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.ALL RIGHTS ARE RESERVED TO iARCHITECTURE.STATEOFMICHIGANARCHITECTJEFFSPIKESNUMBER1301069572JEFF SPIKES, ARCHITECTLICENSE NO. 1301069572B1BAR ROUGH-IN PLAN1/2" = 1'-0"A2.07KITCHENROUGH-INPLAN1AB23CD456ABCD123456DATE 11/12/21REVISIONSNO.DATEPROJECT NO:IA 2119SHEETSMOKEY BONESUTICA, MICOPYRIGHTTHESE DOCUMENTS ARE PROTECTED BY UNITED STATESCOPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLYFOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FORUSE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATIONWITHOUT THE EXPRESS WRITTEN APPROVAL ANDPARTICIPATION OF iARCHITECTURE. REPRODUCTION OFTHESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.ALL RIGHTS ARE RESERVED TO iARCHITECTURE.STATEOFMICHIGANARCHITECTJEFFSPIKESNUMBER1301069572JEFF SPIKES, ARCHITECTLICENSE NO. 1301069572A1KITCHEN ROUGH-IN PLAN3/8" = 1'-0"11'-3"2'-7 1/2"6'-0"2'-7 1/2"8'-2"7'-7"7'-0"7'-0"14'-7"16'-8 1/2"7'-0"2"3'-0"2"3'-2"2"3'-2"2"3'-2"2"3'-2"2"7'-2"2"6'-8"2"2"3'-5 1/4"2"3'-5 1/4"2"3'-5 1/4"2"3'-5 1/4"2"2"7'-9"10'-9 1/2"7'-0"7'-11"3'-4"11'-7 1/4"8'-2"3'-4"7'-0"4'-0"7'-0"3'-0"7'-0"VIEWERPROVIDE 2'-0" X 2'-0"VISION PANEL W/ BLINDS18" VISION PANEL3'-0"7'-0"3'-0"7'-0"PREFINISHED BLACKPAINTED H.M. DOORDOUBLE ACTING"ELIASON" DOORFROSTEDWIRE GLASSSTAINED S.C.WOOD DOORCUSTOMPULL/PUSHFLIPPEDA3.01DOOR ANDWINDOWSCHEDULES1AB23CD456ABCD123456DATE 11/12/21REVISIONSNO.DATEPROJECT NO:IA 2119SHEETSMOKEY BONESUTICA, MICOPYRIGHTTHESE DOCUMENTS ARE PROTECTED BY UNITED STATESCOPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLYFOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FORUSE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATIONWITHOUT THE EXPRESS WRITTEN APPROVAL ANDPARTICIPATION OF iARCHITECTURE. REPRODUCTION OFTHESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.ALL RIGHTS ARE RESERVED TO iARCHITECTURE.STATEOFMICHIGANARCHITECTJEFFSPIKESNUMBER1301069572JEFF SPIKES, ARCHITECTLICENSE NO. 1301069572A4.00EXISTINGEXTERIORELEVATIONSA1EXTERIOR ELEVATIONS1/4" = 1'-0"1AB23CD456ABCD123456DATE 11/12/21REVISIONSNO.DATEPROJECT NO:IA 2119SHEETSMOKEY BONESUTICA, MICOPYRIGHTTHESE DOCUMENTS ARE PROTECTED BY UNITED STATESCOPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLYFOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FORUSE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATIONWITHOUT THE EXPRESS WRITTEN APPROVAL ANDPARTICIPATION OF iARCHITECTURE. REPRODUCTION OFTHESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.ALL RIGHTS ARE RESERVED TO iARCHITECTURE.STATEOFMICHIGANARCHITECTJEFFSPIKESNUMBER1301069572JEFF SPIKES, ARCHITECTLICENSE NO. 1301069572C1EXTERIOR ELEVATIONS1/4" = 1'-0"A4.01EXTERIORELEVATIONSA1EXTERIOR ELEVATIONS1/4" = 1'-0"1AB23CD456ABCD123456DATE 11/12/21REVISIONSNO.DATEPROJECT NO:IA 2119SHEETSMOKEY BONESUTICA, MICOPYRIGHTTHESE DOCUMENTS ARE PROTECTED BY UNITED STATESCOPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLYFOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FORUSE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATIONWITHOUT THE EXPRESS WRITTEN APPROVAL ANDPARTICIPATION OF iARCHITECTURE. REPRODUCTION OFTHESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.ALL RIGHTS ARE RESERVED TO iARCHITECTURE.STATEOFMICHIGANARCHITECTJEFFSPIKESNUMBER1301069572JEFF SPIKES, ARCHITECTLICENSE NO. 1301069572C1EXTERIOR ELEVATIONS1/4" = 1'-0"Smokey Bones Utica MI Permit Drawings.pdf45%01 of 58